3. Install the Valve - Bath/Shower Application
NOTE: For installations that use a bath diverter spout and a
showerhead, install a twin ell (K-9663) between the valve and the
spout.
Install the valve on the support framing so the UP mark on the
valve is facing downward.
If the hot water supply is connected to the cold inlet, the cap
assembly must be rotated 180° to ensure proper orientation; see
the enlarged view showing the cap rotated 180°.
Install elbows and adapters (if needed) to 3/4 copper tubing of
the proper length. Apply thread sealant, and connect the piping
to the bath and shower outlets of the valve.
This feature faces downward
for bath/shower installation.
To
Showerhead
Cold Inlet
Cold
Supply
Hot
Inlet
10"
(25.4 cm)
To Spout
Twin
Ell
Hot
Supply
1150733-2-A 6 Kohler Co.