Roughing-In
NOTICE: All dimensions are nominal. The stud opening tolerance is +1/4 (6 mm) and -0 (0 mm).
Carefully measure your fixture before determining enclosure size. When a fire-rated wall is specified,
dimensions are to the inside of the wall board. Some shimming between the stud frame and the fixture
may be required. Dimensions given in the roughing-in information are crucial for proper installation.
Construct the framing and plumbing accurately.
NOTE: If a firewall is required, increase the roughing-in dimensions according to the thickness of the
firewall material. Stud opening dimensions must be measured toward the exposed side of the wall
material.
NOTE: If the unit will be installed against a masonry wall, make provisions for plumbing connections.
Construct a separate frame wall a minimum of 6 (15.2 cm) from the masonry wall.
1-1/4"
(3.2 cm)
K-9948
K-9949
Flange Detail
60" (152.4 cm)
55-1/8" (140 cm)
32"
(81.3 cm)
16-13/16"
(42.7 cm)
3-9/16"
(9 cm)
3-3/8" (8.6 cm)
1-11/16" (4.3 cm)
4-3/4"
(12.1 cm)
9/16" (1.4 cm)