8. Make the Electrical Connections
NOTE: The product model number is printed on a label on the pump side of the overflowing bath. This
label also identifies the electrical rating of the product. All whirlpools come equipped with a wiring
junction box and are designed to operate between 208 VAC and 240 VAC at either 50 HZ or 60 Hz.
WARNING: Risk of electrical shock. Make sure the power has been disconnected before performing
the following procedures. Refer to the “Important Information” section.
WARNING: Risk of electrical shock. To reduce the risk of electrical shock, connect the pump to a
properly grounded Ground-Fault Circuit-Interrupter (GFCI) or Earth-Leakage Circuit-Breaker (ELCB).
This will provide additional protection against line-to-ground shock hazard. A 208-240 V, 20 A, 50/60
Hz dedicated circuit is required.
IMPORTANT! The load neutral is not used. There should be no connection to the load neutral terminal
on the Ground-Fault Circuit-Interrupter (GFCI) breaker. The green wire with the yellow stripes is the
equipment ground and needs to be connected to the neutral bus in the main circuit breaker box.
The overflowing bath control and system have been pre-wired at the factory. A licensed electrician
should make a routine service connection to the junction box.
Connect service to the junction box. The junction box contains blue, brown, and green with yellow
stripe colored wires.
Follow local electrical codes. Bond in accordance with national and local codes.
A wiring harness has been pre-wired at the factory, allowing communication between the keypad,
all features, and the control. No additional wiring is required, but ensure that all wires are securely
fastened.
NOTE: Your wiring harness included an antenna for the optional remote control. Do not alter or damage
this antenna during installation.
* Connections to be Made
at the Circuit Breaker
S/N
Neutral Bus (In
Breaker Box)
Typical Two-Pole
Circuit Breaker
with GFCI
* Line Neutral
(White Curly
Wire)
Ground (Green
with Yellow Stripes)
*L1
No Connection
(Load Neutral)
Field Wiring (From
Junction Box to
GFCI Breaker)
Electrician to provide suitable
strain relief cable.
Blue (L1)
*L2
240 V
120 V
240 V
120 V
Bond in accordance with
national and local codes.
Open bonding lugs are
located at the top of the
junction box.
Typical Wiring Connection for North America
Wire Connector
From Control
Brown (L2)
Wire Connectors
* Equipment Ground
NL1L2
120/240 VAC Source
Breaker Box
In-line Heater
Control
Junction Box
Heater Electrical Cord
Pump Electrical Cord
Wiring Harness
Heater Junction Box
Kohler Co. 11 1054216-2-A