Using Your Bath (cont.)
As the pump/motor turns on and water begins to circulate, the light will change to solid green, and
will stay on as long as the overflowing bath is running.
Verify that the indicator light for the heater is on when the overflowing bath is in operation. This
indicator light is located on the underside of the heater box, and is near the subfloor at the pump
end of overflowing bath. If the light is not on when the overflowing bath is running, press the reset
button located to the right of the indicator light on the heater box.
Press the On/Off control switch again to turn off the overflowing bath. The orange light in the
On/Off switch will temporarily turn on to indicate the end of the operating mode. The green light
in the On/Off control switch will then start to blink automatically until the overflowing bath is
drained below the overflow channel sensors or restarted.
NOTE: A built-in timer automatically stops the bath after approximately 20 minutes of operation.
16. Chromatherapy Light Operation (if equipped)
NOTE: These directions pertain to the use of the mounted control pad only. For more information, see the
Test the Remote Control section.
If the chromatherapy lights are turned off, press the button on the control pad (located on the
opposite side of the overflowing bath. The chromatherapy lights will begin to cycle through each of
the colors (sweep mode).
When the chromatherapy lights are in sweep mode, you can lock in one color light by pressing the
control button.
When an individual color is locked in, press the control button to turn the chromatherapy lights
off.
17. Troubleshooting Procedures
For warranty service, contact your dealer or wholesale distributor. This Troubleshooting Guide is for general
aid only. Contact a Kohler Authorized Service Representative or a qualified electrician to correct all electrical
problems. For warranty service, contact your dealer or wholesale distributor.
Symptoms Probable Causes Recommended Action
1. Green light in On/Off
control switch flashes
before the bathing well is
full of water.
A. Spout fills directly into overflow
channel.
A. Adjust/reinstall the spout to fill
directly into the bathing well.
Refer to the installer/dealer.
B. One or both butterfly valves do
not work.
B. Check the butterfly valve wiring
or replace the butterfly valves.
Refer to the installer/dealer.
C. Control does not work. C. Check the wiring or replace the
control. Refer to the
installer/dealer.
2. Product does not start. A. No power to unit. A. Turn on the power to the unit, or
correct the source of the power
loss. Refer to the installer/dealer.
B. Water does not cover the overflow
channel sensors.
B. Fill the bathing well until water
flows over the bathing well rim,
into the overflow channel, and
covers the overflow channel
sensors. Suggested fill level is to
the drain overflow.
C. On/Off control switch does not
light up or flash when the unit is
running or filled as required.
C. Check the wiring or replace the
On/Off control switch. Refer to
the installer/dealer.