3. Install the Trim
NOTE: If you are installing the K-T10422 trim, proceed to the
Install the Trim - K-T10422 section of this guide.
Firmly press the valve stem adapters onto each valve stem.
Secure the valve stem adapters to the valve with the correct
length screws, as selected in the Install the Valve Stem Adapters
section of this guide.
Thread the two threaded studs into the threaded holes of the
valve.
Place the front plate assembly over the threaded studs.
NOTE: If the front plate assembly does not lay flat on the wall
surface, loosen the nuts and adjust the threaded studs, then tighten
the nuts. The maximum distance between the threaded studs from
the wall is 7/16 (1.11 cm).
Visually inspect the front plate assembly to ensure that the foam
seal is completely covering the wall opening. If not, stop the
installation and repair the wall opening.
Place the escutcheon against the wall. The drain hole in the
escutcheon should face downward in the 6 o’clock position.
Thread the handle assemblies onto the hubs of the front plate
assembly to secure the escutcheon in place. The volume control
handle assembly (top) should be at the 12 o’clock position. The
thermostatic valve handle assembly (bottom) should be at the 6
o’clock position.
Thermostatic Valve
Valve Stem Adapter
Finished Wall
Front Plate Assembly
Escutcheon
Screws
Threaded Studs
Nuts
Handle Assembly