Page view 160
9.8
Section 9
Disassembly
Figure 9-29. Removing the Spark Advance Module
(Applicable Models).
4. Remove the three (each side) hex. flange screws
securing the outer baffles. Note the location of
any lifting strap and position of the two short
screws (one each side on bottom) for reassembly.
See Figure 9-30.
Figure 9-31. Removing Outer Baffles.
5. Remove the outer baffles on both sides. See
Figure 9-31.
6. On engines equipped with a metal grass screen,
remove the screen before removing the blower
housing. See Figure 9-32. Plastic grass screens
can be removed after the blower housing is
removed.
Figure 9-28. Remove B+ Lead from Terminal Plug.
3. The rectifier-regulator does not have to be
detached from the blower housing. If the engine is
equipped with SMART-SPARK
the SAM module
should be removed from the cylinder baffle or
blower housing. See Figure 9-29. The module
willing hang loose as part of the wiring harness.
Figure 9-30. Note Location of Two Short Screws.