Kohler K-1914-GRW-0 Installation Guide Page 42

  • Download
  • Add to my manuals
  • Print
  • Page
    / 168
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 41
Troubleshooting (cont.)
It is normal to hear the compressor run for up to 90 seconds after the door is raised. The
compressor is located inside the door and is inflating the door seal.
If the door is fully raised for more than 20 minutes when there is no water in the bath,
the seals will automatically deflate.
It is normal to hear the solenoid valve, located inside the door, open and expel air when
the water level falls below the sensors. The valve is deflating the door seal.
Water coming from the bottom of the door and entering the receptor tray is normal when
it is caused by the bather moving about in the bath when it is completely full. Excessive
splashing will cause water to run over the top of the inflated seals into the receptor tray.
Water dripping into the receptor tray as the seals deflate is normal. Water collects on the
seal during use and falls into the receptor tray when the seals deflate.
Troubleshooting the Airjet System
Symptoms Probable Causes Recommended Action
1. Bath with airjets does not
start.
A. No power to blower motor. A. Set/reset GFCI or RCD breaker;
check wiring.
B. User keypad cable loose or
damaged.
B. Check wire connections. If
necessary, replace user keypad
cable.
C. User keypad does not work. C. Check wire connections. Replace
user keypad.
D. Blower motor does not work. D. Replace blower motor.
2. Blower motor starts, but
there are few or no
bubbles.
A. Blower motor is disconnected. A. Connect blower motor to air
harness.
B. Blower motor air flow is
restricted.
B. Clean the area around the blower
motor. Ensure adequate
ventilation.
3. Bath stops automatically
before 18 minutes.
A. GFCI or RCD trips. A. Identify source of fault and
correct.
B. Motor overheated and protection
device activated.
B. Check for blockage at motor
vents. Remove blockage and
allow motor to cool.
4. Bath does not stop
automatically after 22
minutes.
A. Blower motor does not work. A. Replace blower motor.
5. Blower motor does not
stop when power button
on user keypad is
pressed.
A. User keypad cable loose or
damaged.
A. Check wire connections. If
necessary, replace user keypad
cable.
B. User keypad does not work. B. Replace user keypad.
6. Blower motor operates
but variable speed feature
does not work.
A. User keypad cable loose or
damaged.
A. Check wire connections. If
necessary, replace user keypad
cable.
B. User keypad does not work. B. Replace user keypad.
C. Blower motor does not work. C. Replace blower motor.
7. Automatic purge cycle
does not occur.
A. Blower motor does not work. A. Replace blower motor.
1128535-2-F 42 Kohler Co.