Important Information
NOTE: This product is designed for installation with the electrical and water supplies located through
either the wall or the floor.
Grounding Instructions
This product should be grounded. In the event of an electrical short circuit, grounding reduces the
risk of electric shock by providing an escape wire for the electric current. This product is equipped
with a cord having a grounding wire with a grounding plug. The plug must be plugged into an
outlet that is properly installed and grounded.
WARNING: Risk of electric shock. Improper use of the grounding plug can result in a risk of
electric shock.
If repair or replacement of the cord or plug is necessary, do not connect the grounding wire to either
flat blade terminal. The wire with insulation having an outer surface that is green with or without
yellow stripes is the grounding wire.
Check with a qualified electrician or service personnel if the grounding instructions are not
completely understood, or if in doubt as to whether the product is properly grounded.
This product is factory equipped with a specific electric cord and plug to permit connection to a
proper electric circuit. Make sure that the product is connected to an outlet having the same
configuration as the plug. No adapter should be used with this product. Do not modify the plug
provided if it will not fit the outlet, have the proper outlet installed by a qualified electrician. If
the product must be reconnected for use on a different type of electric circuit, the connection should
be made by qualified service personnel.
Tools and Materials
Before You Begin
WARNING: Risk of electric shock. Disconnect power before servicing.
WARNING: Risk of electrical shock. Connect only to a properly-grounded, grounding-type
receptacle which is protected by a Ground-Fault Circuit-Interrupter (GFCI). Do not remove the
grounding pin or use a grounding adapter.
CAUTION: Risk of hazardous gases. If a new toilet is not installed immediately, temporarily place
a rag in the floor flange opening.
NOTICE: The Canadian Electric Code requires receptacles installed in bathrooms to be located at least
39-3/8 (1 M) from a bath or shower if practical, but in no case less than 19-11/16 (500 mm). If the
installation is in Canada, install this unit in accordance with the Canadian Electrical Code, Part 1.
Masking
Tape
Pencil or Felt
Tip Marker
Assorted
Screwdrivers
Supply Stop
5/16" T-Bolts and Wax Seal
Drill and 1/4" bit
Caulk Gun
Caulk
Rags
Silicone Grease
or Soap
1221754-2-B 2 Kohler Co.