- 6 -
VOLUME CONTROL. If necessary, you can adjust the
flow of water with adjusting screw. Decrease the flow by
turning the screw downward or increase the flow by turn
ing the screw upward. The screw must be locked after
adjustment with the locknut.
TRIP LEVER ASSEMBLY. When the trip lever arm is at
rest, rotor arm should not contact bottom of lift chain. If
necessary, bend trip lever arm downward to maintain
clearance.
ROTOR ASSEMBLY. The rotor arm should rest on the
bottom of lift wire loop.
HOW TO SERVICE THE ROCHELLE AND
PALARRE TOILETS
The following instructions are used to replace the valve as
sembly of the K-4859-EB Palarre and K-3385-EB
Rochelle.
Before beginning replacement procedures, turn off
water supply. Flush the toilet to drain water from tank.
REPLACING THE PLUNGER AND SEAT ASSEMBLY ON
EXISTING VALVE.
1. Turn off water supply. Remove cap assembly by un
screwing the two cap screws. Remove plunger assem
bly and old Oring.
2. From inside the valve, remove old seat with a seat
wrench.
3. Thread in new seat. Insert new plunger subassembly
in order shown in Fig. #14. Assemble new Oring to
cap and reassemble valve. Turn on water.
REMOVING OLD FLUSH VALVE
1. Turn off water supply. Disconnect float ball from float
rod.
2. Loosen locknut securing supply tube to tank.
3. Remove trip lever chain from trip lever.
4. Loosen screw in valve seat until seat clamp falls off.
5. Remove flush valve assembly.
INSTALLATION OF NEW FLUSH VALVE
1. Refer to Figs. #14 and #15. Insert lift wire through
hole in guide. Insert rotor arm into lift wire. Thread rotor
assembly into valve body.
2. Place long end of rim flush tube over rim flush opening
on valve.
3. Assemble rubber seat gasket onto seat.
4. Thread rubber gasket onto hush tube. Slide hush tube
over supply tube.
5. Set the seat clamp into center of tank outlet hole.
6. Refer to Fig. #15. Place valve into tank, making sure
that the rim flush tube is inserted into the rim flush sup
ply; supply tube is through open supply hole in bottom
of tank; and the clamp screw hole aligns with the open
ing in the seat clamp.
7. With plastic collar on screw insert, thread in seat clamp
and tighten.
8. Attach flush ball to lift wire.
9. Assemble locknut to hush tube. Tighten locknut.
10. Insert float rod into float guide. Insert float ball.
NOTE: Adjust float rod to obtain the correct water level.
For proper timing, turn the timing screw downward to
decrease flow or upward to increase flow.
11. Reconnect flush valve to the water supply. Turn on sup
ply.
SERVICING THE FRENCH CURVE TOILET
SEAT (NEW STYLE, K-4653)
1. Locate and snap open the two hinged lids that cover
the bolt holes as shown in Fig. #16.
French Curve Seat Removal
Fig. #16
Hinged Lid
Washer
Nut
2. TO REMOVE SEAT. Unscrew the bolts and catch the
nuts from below. Pull seat and bolts away from toilet.
Remove the washers from the toilet.
3. TO REATTACH SEAT. Locate and snap open the two
hinged lids that cover the bolt holes. Slip bolts through
hinge from above. Slide washers onto mounting bolts.