Kohler K-1652-NA Installation Guide Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 44
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
1. Locate the Main Unit
WARNING: Risk of property damage. There should be a minimum of 12 (30.5 cm) of air space
around the steam generator at all times. This provides an area for the heat generated by the unit to
dissipate.
IMPORTANT! The generator must be upright, accessible, and on a level surface. The access panel and
drain valve must be unobstructed and allow for easy access.
IMPORTANT! The required service access for the steam generator must be 20 (50.8 cm) in height and 13
(33 cm) in width.
IMPORTANT! For optimum performance, install the steam generator below the level of the steam head
and as close as possible to the steam head. The unit should be installed within 25 ft (7.62 m) of the steam
head in a dry, well-ventilated area.
Determine the location of the steam generator. Allow for a 12 (30.5 cm) air gap on all sides of the
steam generator. Take into account for clearance for the required drain/spill pan (not supplied).
Place the drain/spill pan in the determined location.
Set the steam generator on top of the drain/spill pan.
Confirm there is a 12 (30.5 cm) gap on all sides of the steam generator. Reposition if necessary.
Steam Outlet
Drain/Spill Pan
Pressure
Relief Valve
Maintain a 12" (30.5 cm)
space around the unit.
Inlet
Drain (install
per applicable
codes)
RJ-12
1008019-2-J 6 Kohler Co.
Page view 5
1 2 3 4 5 6 7 8 9 10 11 ... 43 44

Comments to this Manuals

No comments